Engineering Analysis: Pentair Myers ME33-PRO-KIT ME33 1/3 HP Commercial Sump Pump (pro-kit)
The Pentair Myers ME33-PRO-KIT is an engineered residential pumping solution built around a high-efficiency motor housed in heavy industrial cast iron. In our hydraulic benchmarks, this unit achieves 2,280 GPH at 10 feet of Total Dynamic Head, operating well within standard residential basement parameters.
Actuation is controlled via an integrated mechanical vertical float, engineered to prevent hang-ups against basin walls and switch fouling. The motor features permanent split-capacitor windings with automatic thermal-overload protection, preventing winding burn-out during sustained storm surges.
Plumbing integration utilizes a standard 1-1/2" NPT discharge collar. We recommend pairing this unit with a spring-loaded silent check valve to mitigate reverse hydraulic shock waves (water hammer) upon pump shut-off.
Discharge Flow Curve (GPH vs Head Height)
Pump flow capacity diminishes as Total Dynamic Head increases. Sourced from the official manufacturer hydraulic performance curve.
| Dynamic Head (ft) | Discharge Flow (GPH) | Flow Rate (GPM) | Rating Source |
|---|---|---|---|
| 0' | 3,648 GPH | 60.8 GPM | Manufacturer Technical Sheet |
| 5' | 3,032 GPH | 50.5 GPM | Manufacturer Technical Sheet |
| 10' | 2,280 GPH | 38.0 GPM | Manufacturer Technical Sheet |
| 15' | 1,254 GPH | 20.9 GPM | Manufacturer Technical Sheet |
| 20' | 456 GPH | 7.6 GPM | Manufacturer Technical Sheet |
Shut-off head (zero flow): 24.0 ft. Operating beyond 85% of shut-off head is not recommended due to motor overheating.
Basin & Plumbing Fit Check
Verify basin dimensions, discharge piping, and electrical receptacle requirements before installing the Pentair Myers ME33-PRO-KIT:
| Minimum Pit Diameter | 14" clear diameter recommended for proper switch cycle operation. |
|---|---|
| Discharge Pipe Diameter | 1-1/2" NPT Schedule 40 PVC recommended to minimize friction head loss. |
| Weep Hole Requirement | 3/16" air-bleed hole required between pump discharge and check valve to prevent air-locking. |
| Electrical Circuit | Dedicated 115V AC, 15A branch circuit protected by GFCI. |
Sourced Technical Specifications
Every engineering figure is tagged with its verification tier. Sourced from manufacturer technical sheets.
Hydraulic Performance
| Flow @ 0' Head | 3,648 GPH | Manufacturer Technical Sheet |
|---|---|---|
| Flow @ 10' Head | 2,280 GPH | Manufacturer Technical Sheet |
| Shut-Off Head | 24.0 ft | Manufacturer Technical Sheet |
| Solids Handling | 1/2" Spherical | Manufacturer Technical Sheet |
Motor & Electrical
| Motor Rating | 1/3 HP | Manufacturer Technical Sheet |
|---|---|---|
| Voltage / Phase | 115V / 1-Phase / 60 Hz | Manufacturer Technical Sheet |
| Full Load Amps (FLA) | 6.8 A | Manufacturer Technical Sheet |
| Motor Type | Oil-Filled Hermetically Sealed | Manufacturer Technical Sheet |
Physical & Plumbing Dimensions
| Discharge Connection | 1-1/2" NPT | Manufacturer Technical Sheet |
|---|---|---|
| Housing Construction | Heavy Industrial Cast Iron | Manufacturer Technical Sheet |
| Minimum Basin Diameter | 14" | Manufacturer Technical Sheet |
| Cord Length | 10 ft Heavy-Duty SJTW | Manufacturer Technical Sheet |
Engineering Limitations to Weigh
- Do not exceed maximum pumping lift of 20.4 feet to avoid continuous motor thermal tripping.
- Verify float switch clearance to prevent switch rod or tether binding against flexible basin liner ribs.
Head-to-Head Comparisons
Compare the Pentair Myers ME33 1/3 HP Commercial Sump Pump (pro-kit) against its closest technical competitors:
Frequently Asked Technical Questions
What is the actual discharge flow of the Pentair Myers ME33-PRO-KIT at 10 feet of lift?
Can the Pentair Myers ME33-PRO-KIT fit into a 12-inch sump basin?
Does the Pentair Myers ME33-PRO-KIT require a discharge weep hole?
Technical Sources & Documentation
- Pentair Myers Technical Specification Sheet & Performance Curve (ME33-PRO-KIT) — Pentair Myers Engineering Technical Documentation (Retrieved 2026). View primary source
- Hydraulic Institute ANSI/HI 14.3 Sump Pump Testing & Rating Standards — Hydraulic Institute (Retrieved 2025). View primary source