How the math works
Pumpendium mathTotal dynamic head (TDH) = vertical lift + friction loss. Friction uses the Hazen-Williams equation for PVC (C = 150): loss in feet = 10.44 × equivalent length × (GPM ÷ 150)1.852 ÷ inside diameter4.8655. Equivalent length = vertical pipe + horizontal run + each fitting's equivalent length (for 1-1/2 in pipe: 4 ft per 90-degree elbow, 7.5 ft for a silent check valve, 13 ft for a swing check valve).
LimitsA pump's maximum head is where its flow drops to zero, so a pump with only a little head to spare moves very little water at your height. Use the maker's flow curve to read the flow at your TDH. Very long runs, many fittings or an undersized pipe raise friction quickly.
Questions
What is total dynamic head?
It is the total height the pump has to push against: the vertical lift plus the extra resistance of the pipe, elbows and check valve at your flow rate.
Why does pipe size matter so much?
Friction falls steeply as the pipe gets wider. At 40 GPM, 1-1/4 in pipe loses more than twice as much head per foot as 1-1/2 in pipe.
How much head should I have to spare?
Pick a pump whose curve still delivers the flow you need at your TDH. As a rough screen, a maximum head well above your TDH (we flag 25% or more) leaves room for useful flow.