Quick verdict
Reach for the VCL-24ULS when a big furnace, a commercial-size coil or several appliances feed one pump and the smaller half-gallon VCMA tanks cycle too often. Its doubled tank and much larger motor give headroom. The trade-off is a 120 °F water limit, lower than the VCMA range, and a bulkier box.
Who it fits, and who should skip it
A good fit if
- Several appliances drain into one pump and a half-gallon tank fills too fast.
- Your tubing climbs further than a 20 ft pump handles comfortably.
- You want a safety switch that can stop the equipment or sound an alarm.
Look elsewhere if
- Condensate arrives hotter than 120 °F, as from some boilers.
- Space is tight beside a small air handler; the case is about a foot long.
Specifications
Motor
| Horsepower | 1/18 HP |
|---|---|
| Voltage | 115 V, 60 Hz |
| Amps and watts | 2.5 A, 148 W |
| Motor type | Thermally protected, fan-cooled concentric motor; stainless steel shaft |
Figures: Amazon listing B009HEJXN0, Little Giant VCL-24ULS 553201.
Performance
| Max flow | 270 GPH at a 1 ft lift |
|---|---|
| Max head | 24 ft shut-off |
| Shut-off pressure | 10.4 PSI |
Figures: Amazon listing B009HEJXN0, Little Giant VCL-24ULS 553201.
Switch
| Switch type | Automatic, with a safety switch for equipment shut-down or an alarm |
|---|
Figures: Amazon listing B009HEJXN0, Little Giant VCL-24ULS 553201.
Build
| Discharge | 1/4 in FNPT x 3/8 in OD barbed, for 3/8 in ID vinyl tubing |
|---|---|
| Tank | 1 gallon ABS tank; galvanized steel tank cover |
| Wetted parts | Polypropylene impeller; acetal discharge adapter |
| Max water temperature | 120 °F |
| Power cord | 6 ft with 115 V plug |
| Dimensions | 12.11 x 6 x 10.4 in |
| Weight | 7.8 lb |
| Replacement check valve | CV-15/20 brass, item 599063, fits the VCL-24 |
| Warranty | 1-year manufacturer |
Figures: Amazon listing B009HEJXN0, Little Giant VCL-24ULS 553201; Little Giant VCMA-20 Series product page, parts and accessories.
Installation and setup
The VCL-24ULS is a box of about a foot long and a little over ten inches tall, so measure the floor space or wall beside the furnace before ordering. Set it below the lowest appliance drain, where every incoming line can fall into the tank.
The outlet is unusual: a 1/4 in female pipe thread with a 3/8 in OD barb, meant for 3/8 in ID vinyl tubing. That means you can thread on a hard fitting if a tubing run is not wanted. Take the discharge straight up first, then run it toward the drain. The plug is a standard 115 V type on a 6 ft cord, so a nearby outlet that is always live is the simplest power source; avoid one shared with a fan or anything that switches off.
The safety switch needs low-voltage wiring to the furnace, air conditioner or dehumidifier control, or to an alarm bought separately. The listing calls for basic wiring knowledge, so hire a technician if the thermostat circuit is unfamiliar.
Switch and sizing notes
A float starts and stops the motor without any setting. The separate safety switch is the reason to buy the ULS version: if the pump fails and the water keeps rising, it can shut down the furnace, air conditioner or dehumidifier, or trigger an audible alarm you add.
The listing gives two performance points, 270 GPH at a 1 ft lift and a 24 ft shut-off, with no table between them. Flow falls steadily as height rises, so treat the shut-off as a limit, not a working height. For an ordinary single furnace and a modest climb, the VCMA-20ULS publishes flow at each height and is smaller. The furnace and AC pump list sets the larger tank against the compact choices.
Ownership and maintenance
Treat the tank like any condensate reservoir: unplug it, lift the cover, rinse out the slime and make sure the float rides freely. The polypropylene impeller and acetal adapter resist the mild acidity of furnace water, but the residue still builds up.
Little Giant sells a brass CV-15/20 check valve, item 599063, that it lists for the VCL-24, plus plastic CV-10 and CV-14/24 valves for VCL pumps with date codes on or before 25J. Read the date code on your pump before ordering a valve. The listing gives a one-year warranty.
Pros and cons
Pros
- One-gallon tank cycles less often than half-gallon models.
- 270 GPH at 1 ft covers several appliances at once.
- Threaded outlet accepts tubing or a pipe fitting.
- Maker lists a specific brass check valve for it.
Cons
- Water limit of 120 °F is lower than the VCMA's.
- No published flow figures between 1 ft and shut-off.
- Larger and heavier than compact pumps.
Alternatives worth comparing



Final verdict
Pick the VCL-24ULS when one pump serves a large furnace or several appliances and a half-gallon tank would short-cycle. For one unit with a short climb, a VCMA model is smaller and takes hotter water.
Where to buy
Each button opens this exact model's listing. We may earn a commission on tracked links; it never changes what we publish. Disclosure
Questions buyers ask
What is the difference between the VCL-24ULS and the VCMA-20ULS?
The VCL-24ULS has a 1 gallon tank, a 1/18 HP motor rated 270 GPH at 1 ft and a 24 ft shut-off. The VCMA-20ULS has a half-gallon tank, a 1/30 HP motor and a 20 ft shut-off, but takes water up to 140 °F.
What tubing fits the VCL-24ULS?
The outlet is a 1/4 in female pipe thread with a 3/8 in OD barb, sized for 3/8 in inside-diameter vinyl tubing. Tubing is not in the box with this version, so buy enough to reach the drain.
Which check valve do I need for a VCL-24ULS?
Little Giant lists the brass CV-15/20, item 599063, for the VCL-24, along with CV-10 and CV-14/24 valves for VCL pumps dated 25J or earlier. Match the valve to the date code stamped on your unit.
Can the VCL-24ULS take boiler condensate?
Only if the water reaches the tank at 120 °F or cooler, which is the listed limit. Hotter discharge should cool first, or go to a pump rated for higher temperatures.