Guide · Circulator pumps

Grundfos Comfort System and UP circulators: installation and troubleshooting

Grundfos makes two kinds of small pump that homeowners meet: the Comfort System for instant hot water at the tap, and UP and UPS circulators for heating loops. Grundfos's UP Series data booklet covers both.

By Pumpendium Editorial · Updated November 2026

The short answer

The Grundfos Comfort System pairs a small UP15-10SU7P pump at the water heater with a Comfort Valve under the farthest sink. The pump pushes hot water toward that sink and back through the cold line until the valve closes at about 100 °F, so no return line is needed. If hot water never arrives, check the timer, the valve and the pump's power first.

How the Comfort System works without a return line

Most hot water recirculation systems need a dedicated return pipe from the farthest fixture back to the heater. The Comfort System avoids that. Grundfos describes it as a pump plus a patented Comfort Valve installed at the fixture farthest from the water heater. With its built-in timer, the pump circulates hot water along the hot line, through the valve and back to the heater using the cold-water pipe as the return.

The valve is temperature-sensitive. As the water reaching it warms to about 100 °F, it closes, so the hot line stays full of hot water and the cold line is not flooded with heat. Grundfos claims the system saves up to 16,000 gallons of water a year per household, based on average modern usage, and uses less energy than a 25 W light bulb.

What is in the Comfort System kit

The Comfort System 595916 kit contains one pump, one Comfort Valve and two flex hoses for the valve. The pump is the UP15-10SU7P/TLC, a small open-system circulator built for domestic hot water. The table lists Grundfos's figures for it. The flow is small on purpose: the pump only needs to keep a single hot line warm, not move water to several fixtures at once, which is why it draws so little power. Grundfos also sells the Comfort Valve on its own, so a failed valve can be replaced without changing the pump.

Grundfos Comfort System pump UP15-10SU7P/TLC, from the UP Series data booklet
ItemGrundfos figure
Power115 V, 0.23 A, 25 W, 1/25 hp
Flow range0 to 6.3 gpm
Head range0 to 5.1 ft
Liquid temperature36 to 150 °F
Maximum system pressure145 psi
Pump connection3/4 in M x 3/4 in FNPT
Comfort Valve connection1/2 in M NPS, to fit a 1/2 in faucet supply
Kit contents1 pump, 1 valve, 2 flex hoses 1/2 in x 12 in

Figures: Grundfos UP Series data booklet, 60 Hz.

Installation basics for Grundfos UP pumps

The booklet sets a few rules that apply to every UP and UPS pump, including the Comfort pump. The motor shaft must always be horizontal. The terminal box should sit to one side of the pump with the conduit entry pointing down. The pump can go in a vertical or a horizontal pipe, and it is for indoor use only.

For the Comfort System, the pump goes at the water heater's hot outlet and the valve goes under the sink farthest from the heater, connected between the hot and cold supply stops with the supplied flex hoses. That arrangement is the installation diagram most people search for.

  1. Turn off the water heater and close the cold supply to it.
  2. Fit the pump on the hot outlet line with the shaft horizontal.
  3. Place the terminal box to one side with the cable entry down.
  4. Install the Comfort Valve between hot and cold stops at the farthest sink.
  5. Restore water, purge air at the fixtures, then plug in the pump.
  6. Set the timer to the hours you want hot water ready.

Recirculation pump not working or running cold

If hot water still takes a long time to arrive, start with the simple causes. Check that the pump has power and that the timer is set to run at the hours you use water; outside those hours the system behaves like an ordinary plumbing run. Confirm the Comfort Valve is at the farthest fixture, not a nearer one, or the far end will still run cold.

If the cold tap at that sink runs warm, the valve is passing hot water into the cold line. Grundfos's valve is designed to close at about 100 °F, so a valve that never closes may be blocked or failed. Grundfos also recommends keeping the system temperature as low as practical, around 140 °F, to avoid calcium buildup, which can also foul the valve.

A pump that hums but moves no water may have trapped air or debris; purge air from the fixtures and check the pump strainer if fitted. The booklet notes that the motor has built-in thermal or impedance protection, so it needs no separate overload.

Noise and condensation

Grundfos gives one specific cause of trouble worth knowing: the surrounding air should always be cooler than the water in the pump. If the room is warmer than the liquid, condensation can form inside the stator housing. A buzzing or rattling pump is more often caused by air in the lines or by mounting with the shaft vertical, which the booklet does not allow. Remount with a horizontal shaft and purge air before replacing anything.

UP15-42F and UPS15-58FC heating circulators

The UP15-42F and UPS15-58FC are different tools: flanged circulators for closed hydronic heating loops rather than domestic hot water. The booklet's selection table gives the UP15-42F a flow range up to 17 gpm and head up to 15 ft, single speed. The UPS15-58FC has three speeds, the same flow range and head up to 19 ft, with a removable built-in check valve that Grundfos says prevents thermo-siphoning. Grundfos's data sheet lowers its maximum fluid temperature with the check valve fitted to 200 °F. For boiler loops, the recirculation pump guide explains where each type fits.

Common mistakes

  • Mounting a UP pump with the motor shaft vertical.
  • Installing the Comfort Valve at a nearby sink instead of the farthest fixture.
  • Running the water heater very hot, which speeds calcium buildup in the valve.
  • Placing the pump where the room is warmer than the water it moves.
  • Using a closed-system heating circulator for potable hot water recirculation.

Products that fit

Questions readers ask

Can a Grundfos recirculation pump work without a return line?

Yes, that is what the Comfort System is for. Its Comfort Valve at the farthest sink lets hot water flow back to the heater through the cold-water pipe, and closes at about 100 °F so the cold line does not stay hot.

Why is my Grundfos recirculation pump not working?

Check power and the timer settings first, then confirm the Comfort Valve is at the farthest fixture and closing properly. Air in the lines and calcium buildup in the valve are other common causes.

Which way should a Grundfos circulator be mounted?

Grundfos requires the motor shaft to be horizontal, with the terminal box to one side and the conduit entry down. The pump itself can sit in a vertical or horizontal pipe run.