Quick verdict
Take the RL-SC33T for a roomy basin where fewer, longer pump cycles matter. The tethered float starts the pump at 13 in and stops it at 5 in, so each run moves a deep slice of water and the motor starts less often. The trade is space: Red Lion wants a basin at least 18 in across, wider than many older pits.
Who it fits, and who should skip it
A good fit if
- Your basin is 18 in or wider and the pump cycles too often today.
- Your lift is around 10 ft, where Red Lion still lists 2,460 GPH.
- You want a float you can unplug and test apart from the pump.
Look elsewhere if
- Your pit is narrow; the vertical-float RL-SC33V suits a 15 in basin.
- The discharge climbs near 20 ft, where flow falls to 960 GPH.
Specifications
Motor
| Horsepower | 1/3 HP |
|---|---|
| Voltage | 115 V |
| Amps | 4.3 A (manual) or 4.4 A (product page) |
| Motor type | Permanent split capacitor, oil-filled, automatic-reset thermal protector |
Figures: Red Lion RL-SC series owner's manual 998495, rev. 005; Red Lion cast iron sump pumps product page.
Performance
| Max flow | 3,350 GPH at 0 ft |
|---|---|
| Flow at 5 ft | 3,000 GPH |
| Flow at 10 ft | 2,460 GPH |
| Flow at 15 ft | 1,860 GPH |
| Flow at 20 ft | 960 GPH |
| Max head | 25 ft (7.6 m) shut-off |
Figures: Red Lion cast iron sump pumps product page; Red Lion RL-SC series owner's manual 998495, rev. 005.
Switch
| Switch type | Tethered float with piggyback plug |
|---|---|
| On / off levels | On at 13 in, off at 5 in; tether 3-1/2 in |
Figures: Red Lion cast iron sump pumps product page; Red Lion RL-SC series owner's manual 998495, rev. 005.
Build
| Discharge | 1-1/2 in FNPT |
|---|---|
| Solids handling | 3/8 in semi-solids |
| Construction | Cast iron, clog-resistant design |
| Power cord | 10 ft |
| Minimum basin | 18 in diameter, 18 in deep |
| Shipping weight | 20 lb in carton |
| Warranty | 3-year limited |
Figures: Red Lion cast iron sump pumps product page; Amazon listing B005X54I5U; Red Lion RL-SC series owner's manual 998495, rev. 005.
Versions
Red Lion builds the RL-SC series in two sizes, each with a tethered or a vertical float. The 1/3 HP pair share one curve.
| Version | Part number | What differs | Listing |
|---|---|---|---|
| RL-SC33T, tethered float | 14942744 | 1/3 HP, on 13 in, off 5 in, basin 18 in or more | View on Amazon |
| RL-SC33V, vertical float | 14942745 | 1/3 HP, same curve, basin 15 in or more | Not linked |
| RL-SC50T, tethered float | 14942746 | 1/2 HP, 5.3 A, 28 ft shut-off, basin 18 in or more | Not linked |
Figures: Red Lion RL-SC series owner's manual 998495, rev. 005; Red Lion cast iron sump pumps product page.
Installation and setup
Red Lion's manual asks for a clean basin at least 18 in deep, and for this tethered model at least 18 in in diameter, so the float can swing through its full arc without touching the wall. Set the pump in the center on a hard, level surface, never straight onto clay, earth or gravel.
Pipe at the full 1-1/2 in size with as few elbows as you can. Fit a union just above the basin cover and a free-flow check valve that will pass 3/4 in solids. Lay that valve horizontally or at no more than 45 degrees, because a vertical valve can trap solids and stick shut. Then drill an air bleed hole, 1/8 in or 3/16 in, between the pump and the valve below the floor line; a spray from it while the pump runs is normal.
Plug the pump cord into the back of the float's piggyback plug, then into a dedicated GFCI outlet mounted at least 4 ft above the floor.
Switch and sizing notes
The float hangs on a short 3-1/2 in tether clipped to the discharge pipe. It lifts and tips as water rises, starting the pump at about 13 in and stopping it near 5 in. That wide band is the main reason to pick the T version: each cycle pumps out roughly 8 in of basin depth, so the motor starts fewer times in a wet week than a pump with a tight vertical switch.
For sizing, Red Lion lists 3,000 GPH at 5 ft, 2,460 GPH at 10 ft, 1,860 GPH at 15 ft and 960 GPH at 20 ft. Work out your total head with the sizing calculator, and use the basin cycle calculator to see how that 13 in to 5 in band plays out in your pit.
Ownership and maintenance
Red Lion recommends inspecting and test-running the system every three months. Check the cords and outlet for damage, clear sediment and debris from the basin, and watch a full on and off cycle. If the pump will not start, plug it directly into the outlet; if it runs that way, the float is at fault, and you can test its piggyback plug for continuity with an ohmmeter while raising the float.
Replacement floats are listed by order number: tethered piggyback 640171 with a 10 ft cord or 640172 with a 20 ft cord, and the RL-SC-RVS vertical float 14942758. A damaged power cord means replacing the whole pump. Coverage is a 3-year limited warranty.
Pros and cons
Pros
- Long pump cycle from a 13 in start level.
- Float tests and swaps apart from the pump.
- Cast iron body with PSC motor.
- Clear GPH figures from 0 to 20 ft.
Cons
- Needs a basin 18 in wide.
- Flow drops sharply near 20 ft.
- Maker sources list slightly different amps.
Alternatives worth comparing



Final verdict
The RL-SC33T fits a wide basin and a lift up to about 15 ft, and its tethered float gives the long cycles that help a motor last. In a tight pit, or with a taller climb, its vertical-float or 1/2 HP siblings make more sense.
Where to buy
Each button opens this exact model's listing. We may earn a commission on tracked links; it never changes what we publish. Disclosure
Questions buyers ask
What is the difference between the RL-SC33T and RL-SC33V?
They share the 1/3 HP motor and curve. The T has a tethered float that runs from 13 in down to 5 in and needs an 18 in basin. The V has a vertical float with a much shorter band and fits a 15 in basin, so choose by pit width and how often you want the pump to start.
How many gallons per hour does the RL-SC33T pump?
Red Lion's product page lists 3,350 GPH with no lift. Real flow depends on height: 3,000 GPH at 5 ft, 2,460 GPH at 10 ft and 1,860 GPH at 15 ft, reaching zero at the 25 ft shut-off head.
Can the RL-SC33T handle laundry water?
Red Lion's product page names laundry areas among its uses and rates it for 3/8 in semi-solids. The manual still limits it to clear water and non-corrosive liquids, so it is not a substitute for a sewage or grinder pump.
Why is there a small hole in the discharge pipe?
With a check valve fitted, trapped air can stop the impeller from priming. Red Lion calls for a bleed hole of 1/8 in or 3/16 in between the pump and the valve, below the floor. If the pump ever runs without pumping, clean that hole first.