Quick verdict
Same 12 GPM class as the smaller RL pumps, but with the motor and stages to push from much deeper. This is the size for a deep drilled well, a long climb to the house or a tank that must hold high pressure. On a shallow well it is oversized and will cycle hard; pick the smaller model there.
Who it fits, and who should skip it
A good fit if
- Deep drilled wells where the pumping level sits low.
- Houses well above the wellhead, adding lift after the well.
- Replacing a 1 HP 2-wire 230 V pump.
Look elsewhere if
- Shallow wells, where a 1/2 HP model does the same work.
- Low-yield wells that cannot keep up with 12 GPM.
Specifications
Motor
| Horsepower | 1 HP |
|---|---|
| Voltage | 230 V, single phase |
| Amps | 10.4 A |
| Wiring | 2 wires plus ground, no box |
Figures: Red Lion 4-inch deep well submersible pump owner's manual 106720101 Rev. 003; Red Lion 4 in Submersible Well Pumps RL Series product page; Red Lion 4 in submersible well pumps RL series spec sheet.
Performance
| Max flow | 12 GPM rating |
|---|---|
| Max head | 434 ft (132.3 m) at shut-off |
Figures: Red Lion 4-inch deep well submersible pump owner's manual 106720101 Rev. 003; Red Lion 4 in Submersible Well Pumps RL Series product page.
Application
| Well size | 4 in casing or wider |
|---|---|
| Check valves | One within 25 ft of the pump, then every 200 ft |
Figures: Red Lion 4-inch deep well submersible pump owner's manual 106720101 Rev. 003.
Build
| Discharge | 1-1/4 in FNPT |
|---|---|
| Materials | Stainless steel shell; thermoplastic discharge and bracket |
| Inlet | Built-in screen; internal check valve |
| Carton | 29 in long, 33 lb |
| Switch type | Runs from an external pressure switch |
| Warranty | Limited, 3 years |
Figures: Red Lion 4-inch deep well submersible pump owner's manual 106720101 Rev. 003; Red Lion 4 in submersible well pumps RL series spec sheet.
Versions
The 1 HP RL12 pump is sold as a 2-wire motor or as a 3-wire motor that ships with its control box.
| Version | Part number | What differs | Listing |
|---|---|---|---|
| RL12G10-2W2V, 2-wire | 14942404 | 230 V, 10.4 A | View on Amazon |
| RL12G10-3W2V, 3-wire | 14942407 | 230 V, 10.4 A; control box included | Not linked |
Figures: Red Lion 4-inch deep well submersible pump owner's manual 106720101 Rev. 003.
Installation and setup
Deep settings raise the stakes on every step. The column of pipe, water and cable is heavy, so a steel safety cable of 3/16 to 1/4 in is not optional, and the torque arrestor above the pump keeps the start-up twist from chafing the cable on the casing. Tape the cable every 10 ft and leave slack on plastic pipe, which stretches under load.
Red Lion asks for positive-sealing check valves only: one within 25 ft of the pump and below the draw-down level, and further valves at 200 ft intervals on settings deeper than that. Missing or leaking valves show up as backspin and up-thrust in the troubleshooting chart, both of which shorten a submersible's life.
Keep the pump at least 5 ft off the bottom and above the screen, and run the well-clearing test before sealing the well.
Switch and sizing notes
The pressure switch feeds the motor directly; at 10.4 A, check its contact rating or add a contactor. A GFCI and fused disconnect are required. The switch settings guide covers the bands.
This size only makes sense when the numbers demand it. Add pumping level, rise to the tank, cut-out pressure in feet and friction; if the total is beyond what the 3/4 HP RL12G07 can handle comfortably, the 1 HP pump with 434 ft of shut-off head is the step up. Check the well's yield too: Red Lion's answer to a well that cannot keep up is a smaller pump, never a bigger one. The deep well picks list other options.
Ownership and maintenance
Watch run times and pressure rather than the pump itself. Short cycling points to the tank, a leak or switch settings; weak output to a clogged screen, low voltage or a drawn-down well. A tripping overload on a 1 HP motor often means low voltage at the end of a long cable, so measure it at the switch while the pump runs.
Red Lion's three-year warranty runs through an authorized reseller and is lost if the motor is opened elsewhere.
Pros and cons
Pros
- 434 ft of shut-off head for deep wells.
- No control box on the wall.
- Built-in screen and check valve.
- Same 12 GPM class as smaller RL pumps.
Cons
- Oversized for shallow wells.
- Start parts sit down the well.
- Heavy column needs careful handling.
Alternatives worth comparing



Final verdict
The RL12G10-2W2V is the RL pump for genuinely deep wells and high-lift houses on 230 V. Size it from total head and well yield; if the numbers fit a 3/4 HP pump, that smaller model will run longer cycles and cost less to run.
Where to buy
Each button opens this exact model's listing. We may earn a commission on tracked links; it never changes what we publish. Disclosure
Questions buyers ask
How deep can the RL12G10-2W2V pump?
Its shut-off head is 434 ft, the height at which flow stops. The practical setting is shallower, because tank pressure and friction use part of that head. Work out total dynamic head before choosing it, and check the setting against the well record.
Does a 1 HP pump give more water than a 1/2 HP one?
Not at low head. All RL12 pumps share a 12 GPM rating; the larger motor and extra stages keep that flow going against more head. On a shallow well, a 1 HP pump simply fills the tank faster and cycles more.
How many check valves does it need?
Besides the built-in valve, Red Lion asks for a positive-sealing check valve within 25 ft of the pump and below the draw-down level, plus one every 200 ft on deeper settings. Never use swing-type valves.
Is there a 3-wire version?
Yes, the RL12G10-3W2V, item 14942407, has the same 230 V, 10.4 A rating and 434 ft shut-off and ships with a control box that holds the start components above ground, where they are easy to reach.