Without a return line, fit a crossover kit: the pump at the water heater and the valve under the fixture farthest from the heater, between hot and cold supplies. With a return line, mount a bronze or stainless circulator on the return near the heater with a check valve. Keep the motor shaft horizontal, time it to your usage and keep the heater near 140 °F.
Choose the layout: crossover or return loop
Look under the water heater and at the far bathroom. If there is only a hot and a cold line to each fixture, you need a crossover system that uses the cold line to carry water back. Grundfos's Comfort System works this way: its Comfort Valve sits at the fixture farthest from the tank and lets water flow from the hot to the cold side until it reaches 100 °F, then closes. The Grundfos Comfort System 595916 kit includes the pump and valve.
If your home has a dedicated return pipe, usually a third line arriving back at the heater, a standalone circulator on that return gives the best result, with no warm water in the cold line. Either way, pumps for drinking water need bronze, brass or stainless steel housings; Grundfos reserves cast iron for closed heating systems.
Installing a crossover system
Shut off the cold supply to the water heater and the power or gas to it, and open a hot tap to relieve pressure. The pump goes on the heater's hot outlet with unions so it can be removed. At the farthest fixture, the crossover valve connects between the hot and cold angle stops and the faucet supply lines. Follow the kit's flow arrows exactly: a reversed pump or valve will not circulate.
- Turn off the heater's energy source and its cold water supply.
- Open a hot tap to drain pressure from the lines.
- Fit the pump on the heater outlet with its arrow pointing away from the tank.
- Install the crossover valve under the fixture farthest from the heater.
- Restore water, bleed air at the far tap, then plug in the pump.
Installing on a dedicated return line
On a loop system, mount the circulator on the return pipe near the heater, pumping toward the heater's cold inlet or drain connection as the system design shows. Fit isolation valves on each side and a check valve so water cannot flow backward through the loop when the pump is off. Some Grundfos models, including the UPS15-58FC, have an integrated removable check valve.
Orientation matters. Grundfos requires the motor shaft to be horizontal, with the terminal box to one side and the conduit entry down; the pump can sit in a vertical or horizontal pipe. Its UP pumps are rated to 145 psi system pressure and for indoor use only. Keep the surrounding air cooler than the water, as Grundfos warns that otherwise condensation can form in the stator.
| Item | Grundfos guidance |
|---|---|
| Motor shaft | Horizontal; terminal box at side, conduit entry down |
| Pipe direction | Vertical or horizontal lines |
| Maximum system pressure | 145 psi |
| Location | Indoor use only |
| Housing for potable water | Bronze, brass or stainless steel |
Figures: Grundfos UP series circulator data booklet, installation and Comfort System pages; Grundfos UPS15-58FC product data.
Setting the timer and aquastat
The timer decides how much the system costs to run. Grundfos's UP 10 comfort pump has a 24-hour timer in 15 minute steps, plus settings for continuous on or off, and some versions add an aquastat adjustable between 95 °F and 150 °F. The Comfort System and the Laing AutoCirc also use built-in timers. Set on periods to start shortly before the household's usual hot water times, for example before morning showers and the evening dishes, and leave the pump off overnight and while the house is empty.
Where an aquastat is fitted, set it a little below the temperature you want at the tap so the pump stops once the loop is warm. Grundfos recommends keeping the operating temperature as low as practical, around 140 °F, to avoid calcium buildup. Reset the clock after any power cut, since a timer running at the wrong hour looks exactly like a failed pump.
First start and checks
With water restored and air bled from the far fixture, plug the pump into a 115 V outlet and switch the timer to on. Within a few minutes the far tap should deliver hot water quickly. On a crossover system, the cold tap at that fixture may run warm briefly; that is how the system returns water and is normal. Listen for gurgling, which means trapped air, and for a buzz that may mean low inlet pressure, since Grundfos sets minimum inlet pressures to prevent cavitation.
If the result is slow, the troubleshooting guide linked below covers timers, valves and scale. For other pump options, see the Laing AutoCirc and the wider recirculation and circulator category.
Common mistakes
- Installing the crossover valve at a fixture close to the heater.
- Mounting the circulator with its motor shaft vertical.
- Using a cast iron circulator on a drinking water loop.
- Leaving the timer on around the clock and wasting energy.
- Forgetting to reset the timer clock after a power outage.
Products that fit

Grundfos Comfort System 595916 Recirculation Pump Kit
Crossover kit with a timed pump and an under-sink Comfort Valve for homes without a return line.

Laing AutoCirc LHB08100092 Recirculation Pump
Brass recirculation pump with a built-in timer, for 115 V circuits.

A. O. Smith APCOM UT1 Recirculation Pump
Under-sink recirculation unit intended for homes with tank-type water heaters.

Grundfos UPS15-58FC Circulator Pump
Three-speed circulator with an integrated check valve, for closed loops only.
Questions readers ask
Where should a hot water recirculation pump be installed?
For crossover kits, at the water heater with the valve under the farthest fixture. For homes with a return line, on that return near the heater, with a check valve and isolation valves. Keep the motor shaft horizontal.
How should I set a recirculation pump timer?
Set on periods to begin shortly before your usual hot water times and off overnight and when the house is empty. Grundfos's comfort pump timers work in 15 minute steps over 24 hours, so short morning and evening windows are easy to set.
Do I need a dedicated return line for a recirculation pump?
No. Crossover systems such as Grundfos's Comfort System use the cold line as the return through a valve at the far fixture. A dedicated return line avoids warm water in the cold tap, but adding one is a larger plumbing job.
Can I plug a recirculation pump into any outlet?
Use a grounded 115 V outlet near the water heater that is always powered. Do not use a switched outlet, which turns the pump off without its timer knowing and resets the clock.