If a Little Giant pump will not turn on, check power and the GFCI, then the switch: diaphragm models fail when the breather tube in the cord is pinched, and float models when the float is dirty or blocked. If it keeps running, look for an air lock from a missing or clogged relief hole.
The Little Giant pumps people troubleshoot
The common models fall into three groups. The 5 Series, including the 5-MSP manual pump and the automatic 5-ASP, is a compact 1/6 hp utility pump with an epoxy-coated cast aluminum housing and an oil-free motor. The 6-CIA-ML is a 1/3 hp cast iron pump with an integral diaphragm switch, used in sump pits and in Little Giant's compact basin systems. The APCP-1700 is an automatic pool cover pump. The table gives Little Giant's figures for each. Knowing which switch your pump uses matters most, because a manual pump, a diaphragm switch and a float each fail in their own way, and the fixes below are grouped by switch type.
| Model | Power | Switch | Shut-off | Discharge |
|---|---|---|---|---|
| 5-MSP | 1/6 hp | None, manual | 26 ft | 1 in FNPT with hose adapter |
| 5-ASP | 1/6 hp | Piggyback diaphragm, on 6-9 in | 26 ft | 1 in FNPT with hose adapter |
| 6-CIA-ML | 1/3 hp | Integral diaphragm | 18 ft | 1.5 in FNPT |
| APCP-1700 | 115 V, 270 W | Automatic, on at 2 in | 26 ft | 1 in FNPT, 3/4 in hose adapter |
Figures: Little Giant 5 Series utility pump spec sheet 996573; Little Giant 6-CIA-ML order page, item 506160; Little Giant APCP-1700 spec sheet M5282.
Little Giant pump not turning on
Little Giant's 6 Series manual starts with power: connect the pump to a dedicated circuit with a GFCI, and check the breaker or fuse. The next cause depends on the switch. Diaphragm switches sense water pressure through a small breather tube that runs inside the power cord; if the cord is kinked or pinched, or the breather tube's opening is blocked, the switch cannot work. Little Giant asks owners to confirm the cord is not kinked and the tube end is clear.
Models with a tethered float fail differently: a float coated with debris or blocked by the basin wall never rises. Clean the float and give it room. If power, cord and float are all fine, the manual's answer is a defective switch, which is replaceable, or a defective motor, which means replacing the pump.
- Confirm the outlet and GFCI are live with another device.
- Check the breaker or fuse feeding the pump circuit.
- Straighten the cord and check the breather tube end on diaphragm models.
- Clean and free the float on tethered models.
- On manual 5-MSP pumps, remember there is no switch at all.
Little Giant pump keeps running
For a pump that will not shut off, the manual lists a float obstruction, a blocked breather tube on diaphragm models, a defective switch, inflow that matches the pump's capacity, and air lock. Air lock deserves attention because it is easy to fix. Little Giant asks installers to drill a 1/8 in or 3/16 in relief hole in the discharge pipe below the floor line; if that hole is missing or clogged, trapped air can stop the pump moving water while the motor keeps running.
Little Giant also notes that its pumps have a bleed hole in the base. Water spraying from that hole is normal and needs no action.
Humming but not pumping, or weak flow
When a Little Giant pump runs but discharges nothing, the manual lists a check valve installed backward, a check valve stuck or plugged, a lift too high for the pump, a plugged impeller inlet and air lock. Check the arrow on the check valve body first; it should point away from the pump. Weak flow adds low voltage and wear from abrasives, which Little Giant says requires a new pump.
The motor carries an automatic-reset thermal protector, so a pump that stops and later restarts on its own is overheating. Little Giant lists overloading or overheating causes and asks for at least 2 hours of cooling before service. The warranty is void if the motor cover, impeller or seals have been removed, so do not open the pump.
Constant cycling and short runs
For a pump that cycles continuously, Little Giant names three causes: no check valve in a long discharge line, so water drains back into the basin; a leaking check valve; and a basin too small for the inflow. The 5 Series offers a low-level diaphragm version, the 5-ASP-LL, that switches on at 2 to 3 in for shallow jobs, which shows how much the switch choice changes cycling. In the compact basin systems, the small tank means short runs are normal.
Pool cover pump and warranty
The APCP-1700 starts when water on the cover reaches 2 in and stops when it falls below 1 in, according to Little Giant's spec sheet. If it will not start, the water is usually too shallow or the pump is not sitting at the low point of the cover. Little Giant's warranty page puts sump, effluent, sewage and grinder pumps on a three-year warranty, and the 6-CIA-ML order page lists 36 months. For a utility replacement, the 5-MSP sits on the submersible utility pump list.
Common mistakes
- Kinking or pinching the cord on a diaphragm switch pump, which blocks its breather tube.
- Skipping the relief hole in the discharge pipe and getting air lock.
- Fitting the discharge check valve backward, so its flow arrow faces the Little Giant pump.
- Opening the motor or impeller housing, which voids the warranty.
- Expecting the manual 5-MSP to start on its own.
Products that fit

Little Giant 5-MSP Manual Utility Pump
1/6 hp manual utility pump with a cast aluminum housing and hose adapter.

Little Giant 6-CIA-ML Under-Sink and Laundry Tray Pump
1/3 hp cast iron pump with an integral diaphragm switch.

Little Giant APCP-1700 Automatic Pool Cover Pump
Automatic pool cover pump that starts at 2 in of water.

Little Giant WRSC-6 Compact Sump Pump Basin System
Preassembled small basin system that Little Giant builds around the 6-CIA-ML pump.
Questions readers ask
Why is my Little Giant pump not turning on?
Check power and the GFCI first. On diaphragm switch models, a kinked cord or blocked breather tube stops the switch; on float models, a dirty or blocked float. If those are fine, Little Giant's manual points to a failed switch or motor.
Why does my Little Giant pump keep running?
Little Giant lists a blocked float, a pinched breather tube, a failed switch, inflow equal to pump capacity and air lock from a missing or clogged relief hole in the discharge pipe.
Is water spraying from my Little Giant pump normal?
Yes, if it comes from the small hole in the base. Little Giant fits a bleed hole to let trapped air out and prevent air lock, and says water spraying from it needs no action.