Guide · Well and sump pumps

Red Lion pumps (RJS-PREM jet, RL-SC sump): setup and troubleshooting

Red Lion, a Franklin Electric brand, sells two pumps people most often troubleshoot: the RJS-PREM cast iron shallow well jet pumps and the RL-SC cast iron sump pumps. Red Lion's manuals and product pages cover both.

By Pumpendium Editorial · Updated November 2026

The short answer

If a Red Lion jet pump runs but will not build pressure, it has usually lost prime, has an air leak in the suction line or is lifting more than 25 ft. If it will not turn on, check power to the pressure switch and whether the switch has closed. For an RL-SC sump pump that will not start, check the outlet, then the piggyback float and the basin clearance.

RJS-PREM jet pumps: models and settings

The RJS-PREM series are cast iron shallow well jet pumps with a dual-voltage capacitor motor and a factory 30/50 psi pressure switch. Red Lion rates them for suction lifts down to 25 ft and backs them with a three-year warranty. Note the horsepower: the RJS-50-PREM is a 1/2 HP pump, despite listings that call it larger. The table shows Red Lion's figures at a 30 psi discharge pressure.

Two settings matter on every install. Red Lion asks for the tank precharge to be 28 psi to suit the 30/50 switch, and for a pressure relief valve able to pass full pump flow at 75 psi. It also says a check valve should never be installed between the pump and the tank.

Red Lion RJS-PREM flow in gallons per minute at 30 psi discharge
ModelPower5 ft lift15 ft lift25 ft lift
RJS-50-PREM1/2 HP12.6106.9
RJS-75-PREM3/4 HP16.713.18.4
RJS-100-PREM1 HP23.219.513.3

Figures: Red Lion RJS-PREM series product page.

Red Lion jet pump not building pressure

Red Lion's troubleshooting guide lists the causes for a jet pump that delivers water but not at rated capacity: leaks in the suction or discharge line, a partly plugged foot valve, suction line, impeller or nozzle, more suction lift than recommended, wrong rotation or low speed, a plugged venturi or diffuser, a motor wired for the wrong voltage and low line voltage at the motor.

Suction air leaks are the most common. The RJS-PREM manual warns that even a pinhole in a joint can stop the pump working properly, so seal every threaded joint and keep the suction pipe sloping steadily up to the pump. Red Lion's suction limit of 25 ft includes draw-down, so a well that drops in summer may push a working installation past its limit.

  1. Shut off power and let a hot pump cool before opening plugs.
  2. Fill the casing through the priming plug until water overflows.
  3. Check every suction joint for leaks with soapy water.
  4. Confirm the motor is wired for your supply voltage.
  5. Clean the nozzle and venturi if flow stays low.

Red Lion jet pump not turning on

For a jet pump motor that will not start, Red Lion lists just two causes: no power reaching the pressure switch, from blown fuses, open switches or loose connections, and a pressure switch that has not closed. Check the breaker and any disconnect, then watch the pressure gauge. If pressure is below 30 psi and the switch has not closed, the switch contacts or its sensing tube may be at fault.

If the pump starts and stops too often, Red Lion points to air leaks in the tank, a wrong switch setting, a waterlogged or wrongly charged tank, or a foot valve that leaks or is stuck open. Never apply power until the pump is primed; the manual warns that running it dry can overheat and damage it.

RL-SC cast iron sump pumps

The RL-SC series are cast iron submersible sump pumps with a 1-1/2 in discharge, a PSC motor and a piggyback float switch, either tethered (T) or vertical (V). Red Lion's product page fixes another catalog error: the RL-SC50V is the 1/2 HP vertical model. The switch type sets the basin you need. Vertical models fit narrower pits and cycle more often; tethered models need more room but run longer between starts. Both share the same motor and curve at each horsepower, so the choice is about your pit, not about pumping power.

Red Lion RL-SC sump pumps from the maker product page
ModelPowerOn / offSmallest basinFlow at 10 ft
RL-SC33V1/3 HP, vertical7.25 in / 2.75 in15 in2,460 GPH
RL-SC33T1/3 HP, tethered13 in / 5 in18 in2,460 GPH
RL-SC50V1/2 HP, vertical7.25 in / 2.75 in15 in3,000 GPH
RL-SC50T1/2 HP, tethered13 in / 5 in18 in3,000 GPH

Figures: Red Lion cast iron sump pumps product page, RL-SC series.

RL-SC sump pump not turning on

Because the RL-SC uses a piggyback float, the quickest test is to unplug the float plug and plug the pump straight into the outlet. If the pump runs, the float switch is the fault; if it stays silent with a live outlet, the pump is. Before that, make sure the float has room to move and the outlet or GFCI has not tripped: a tethered float in a basin narrower than the 18 in Red Lion asks for can hang on the wall. A vertical float needs at least 15 in. The sump pump not turning on guide walks through the rest.

Parts, manuals and the pedestal pump

Red Lion's general troubleshooting guide gives its pressure tanks a five-year limited warranty from manufacture and suggests flushing a new tank through a few pump cycles if the water tastes odd. Red Lion lists repair parts in each owner's manual, and its product pages link the manuals directly: the RJS-PREM series manual, the RL-SC series manual and a general troubleshooting guide. Red Lion's RL-SP33PED pedestal pump is a different design with an adjustable snap-action float for basins 13 in or wider. For shallow well replacements, compare the RJS-75-PREM with others on the shallow well jet pump list.

Common mistakes

  • Installing a check valve between the jet pump and the pressure tank.
  • Powering the jet pump before it is primed.
  • Leaving tank precharge at a random figure instead of 28 psi for the 30/50 switch.
  • Putting a tethered RL-SC in a basin narrower than Red Lion's minimum.
  • Trusting a listing's horsepower instead of the maker's model table.

Products that fit

Questions readers ask

Why is my Red Lion pump not building pressure?

Red Lion lists suction or discharge leaks, a partly plugged foot valve, nozzle or impeller, too much suction lift, a plugged venturi, wrong voltage wiring and low line voltage. Air leaks in the suction line are the most frequent cause.

What precharge does a Red Lion jet pump tank need?

The RJS-PREM manual asks for 28 psi to suit the factory 30/50 pressure switch. Check it with the tank drained and the pump switched off, and recheck it if the pump starts cycling more often than usual.

What is the warranty on Red Lion pumps?

The RJS-PREM jet pumps carry a three-year limited warranty from the date of original purchase, per Red Lion's manual. Red Lion's troubleshooting guide lists five years on its pressure tanks from manufacture.