Quick verdict
The extra motor over the J5 buys depth: Goulds lists a J7 jet for water as deep as 110 ft, where the 1/2 HP pump stops at 90 ft. That makes the J7 the sensible Goulds convertible for a deeper two-pipe well. As with the J5, the jet assembly is separate and the saved documents carry no flow table.
Who it fits, and who should skip it
A good fit if
- Two-pipe wells with water 60 to 110 ft down.
- Replacing an old 3/4 HP convertible on existing pipes.
- Shallow duty today, deep duty later, on one pump.
Look elsewhere if
- Buyers who want a published flow figure for this model.
- Circuits that cannot carry 14.8 A at 115 V.
Specifications
Motor
| Horsepower | 3/4 HP |
|---|---|
| Voltage | 115/230 V single phase |
| Maximum load amps | 14.8 A at 115 V, 7.4 A at 230 V |
| Circuit breaker | 30 A at 115 V, 15 A at 230 V |
Figures: Amazon listing B009EBVD8E; Goulds jet pump installation manual IM102 (third-party copy).
Performance
| Max flow | Not stated on the data sheet |
|---|---|
| Max head | Not stated on the data sheet |
Figures: Goulds jet pump installation manual IM102 (third-party copy).
Jets
| Shallow well adapter | FH7 (nozzle AN018, venturi AD3536) |
|---|---|
| 4 in twin-pipe jets | FT4B-14 for 30-60 ft (28 psi); FT4B-34 for 70-90 ft (29 psi) |
| Deepest 4 in jet | FT4B-18 for 90-110 ft, control valve 30 psi |
Figures: Goulds jet pump installation manual IM102 (third-party copy).
Controls
| Switch type | Pressure switch on the pump (AS4 on J models) |
|---|
Figures: Amazon listing B009EBVD8E; Amazon listing B009EBVCAS (Goulds J5).
Build
| Design | Back pullout; two-compartment motor; nozzle clean-out plug |
|---|---|
| Fittings | Plastic tubing and O-ring fittings, hand tight |
| Weight | 46 lb (listing) |
| Warranty | One year from install or 18 months from date code |
Figures: Amazon listing B009EBVD8E; Goulds jet pump installation manual IM102 (third-party copy).
Installation and setup
The deep-well setup is where the J7 earns its place. A twin-pipe jet hangs in a 4 in or larger well on a suction pipe and a drive pipe; the pump pushes part of its output down the drive pipe to power the jet, which lifts water up the suction side. Lower the jet to the depth band it is chosen for, then seal the well.
Run both pipes so they rise steadily to the pump, with no humps that trap air, and make every joint airtight. A long horizontal offset adds friction; Goulds' manual suggests larger pipe on long runs. For shallow use instead, bolt the FH7 adapter to the pump front and run a single suction line.
Fit a tee at the discharge as a priming port, and keep restrictive valves or filters out of the pump-to-tank line.
Switch and sizing notes
Two settings govern a deep jet: the pressure switch, which starts and stops the pump, and the control valve, which holds back enough pressure to drive the jet. Goulds lists 28 psi for the FT4B-14, 29 psi for the FT4B-34 and 30 psi for the FT4B-18. Set the tank 2 psi below cut-in; the switch settings guide covers the bands.
Choose the jet by depth to water, including draw-down. Water within 60 ft suits the FT4B-14; 70 to 90 ft, the FT4B-34; 90 to 110 ft, the FT4B-18. Larger 4-1/2 in jets also appear in Goulds' chart. If the household demand is high at those depths, a submersible is usually the stronger answer.
Ownership and maintenance
Service is straightforward: the motor and impeller slide out the back without disturbing pipes, and the nozzle can be cleaned through its plug. A diaphragm keeps the seal wet. Goulds covers the pump for one year from installation or 18 months from the date code.
Most deep-jet complaints start in the well rather than the pump: a leaking foot valve, a loose joint on the suction pipe or a control valve set wrongly for the jet. Check those before pulling the motor.
Pros and cons
Pros
- Matched jets listed down to 110 ft.
- Converts between shallow and deep duty.
- Back pullout service design.
- Control valve settings given per jet.
Cons
- Jet or adapter sold separately.
- No flow table in the saved documents.
- Draws 14.8 A on 115 V.
Alternatives worth comparing



Final verdict
The Goulds J7 is the convertible to choose for a two-pipe well with water beyond the J5's range, up to 110 ft. Match the jet and control valve to your depth exactly as Goulds' chart sets out.
Where to buy
Each button opens this exact model's listing. We may earn a commission on tracked links; it never changes what we publish. Disclosure
Questions buyers ask
How deep can a Goulds J7 pump from?
Goulds' jet chart pairs the J7 with the FT4B-18 twin-pipe jet for water 90 to 110 ft down in a 4 in well, with a 30 psi control valve setting. Shallower bands use the FT4B-14 and FT4B-34 jets.
What shallow well adapter fits the J7?
The FH7, which carries nozzle AN018 and venturi AD3536. Bolt it to the front of the pump for water within 25 ft and run a single suction pipe to a foot valve or check valve.
What is the control valve setting for?
A deep-well jet needs pressure in the drive pipe to lift water. The control valve keeps the pump's discharge from dropping below that level. Goulds lists 28 to 30 psi for the J7's 4 in twin-pipe jets.
What breaker does the J7 need?
Goulds' motor data gives a maximum load of 14.8 A at 115 V and 7.4 A at 230 V, with 30 A and 15 A breakers. Change voltage inside the motor cover before wiring.