4 in deep well submersible ยท Red Lion

Red Lion RL12G05-2W2V 2-Wire Deep Well Pump

The RL12G05-2W2V is Red Lion's 1/2 HP, 2-wire, 230 V submersible for 4 in wells: 6 A, 12 GPM rated flow and 212 ft of shut-off head, with no control box.

Model RL12G05-2W2V · part number 14942402 · Updated November 2026

Horsepower
1/2 HP
Voltage
230 V single phase
Max flow
12 GPM rated
Max head
212 ft shut-off (64.6 m)
Discharge
1-1/4 in FNPT, thermoplastic head

Each button opens this exact model's listing. We may earn a commission on tracked links; it never changes what we publish. Disclosure

Quick verdict

In short

This is the plain-vanilla 1/2 HP choice in the RL range: 230 V for modest current, 2-wire for the simplest hookup. It suits a household well where the water is not deep. The trade-off against the 3-wire twin is serviceability, because the start circuit sits inside the motor rather than in a box on the wall.

Who it fits, and who should skip it

A good fit if

  • Replacing a 1/2 HP 2-wire pump on existing 230 V cable.
  • Moderate-depth 4 in wells serving one household.
  • Installers who want the fewest parts above ground.

Look elsewhere if

  • Deep wells where head nears the 212 ft shut-off.
  • Owners who want start parts serviceable without pulling the pump.

Specifications

Motor

Horsepower1/2 HP
Voltage230 V single phase
Amps6 A
Wiring2-wire with ground; start circuit inside the motor

Figures: Red Lion 4-inch deep well submersible pump owner's manual 106720101 Rev. 003; Red Lion 4 in Submersible Well Pumps RL Series product page; Red Lion 4 in submersible well pumps RL series spec sheet.

Performance

Max flow12 GPM rated
Max head212 ft shut-off (64.6 m)

Figures: Red Lion 4-inch deep well submersible pump owner's manual 106720101 Rev. 003; Red Lion 4 in Submersible Well Pumps RL Series product page.

Application

Well sizeDrilled wells of 4 in and up

Figures: Red Lion 4-inch deep well submersible pump owner's manual 106720101 Rev. 003.

Build

Discharge1-1/4 in FNPT, thermoplastic head
Pump shellStainless steel
Built-inSuction screen and internal check valve
Carton34.5 in, 25 lb
Switch typeExternal pressure switch, bought separately
Warranty3 years, limited

Figures: Red Lion 4-inch deep well submersible pump owner's manual 106720101 Rev. 003; Red Lion 4 in submersible well pumps RL series spec sheet.

Versions

Red Lion builds the 1/2 HP RL pump three ways. Pick by the voltage at your well and whether you want a control box.

VersionPart numberWhat differsListing
RL12G05-2W2V, 2-wire, 230 V149424026 A, no boxView on Amazon
RL12G05-3W2V, 3-wire, 230 V149424056 A, control box includedNot linked
RL12G05-2W1V, 2-wire, 115 V1494240112 A, no boxNot linked

Figures: Red Lion 4-inch deep well submersible pump owner's manual 106720101 Rev. 003.

Installation and setup

When replacing an old pump, count the conductors in the drop cable first. Two hot leads plus a ground means a 2-wire motor like this one can go straight back on; three leads plus ground means the old pump was 3-wire, and you either keep that layout with the RL12G05-3W2V or remove the old control box from the circuit.

Set depth from the well record so the pump stays covered at full draw-down, at least 5 ft above the bottom. Use a steel safety cable, a torque arrestor just above the pump and cable clamps at 10 ft intervals. Only positive-sealing check valves are allowed, the first within 25 ft of the pump.

Wire through a fused disconnect and GFCI, bond the green motor lead to ground, and run the well-clearing test through a gate valve before closing the well cap.

Switch and sizing notes

The pressure switch switches both 230 V legs to the motor directly. A typical setup pairs it with a captive-air tank charged a little below the cut-in pressure; see the tank sizing guide for drawdown and run time.

Total head is the sum of pumping level, lift to the tank, cut-out pressure expressed as feet of water, and friction. With 212 ft of shut-off, the 1/2 HP size belongs on wells where that sum stays well short of the limit. Red Lion's manual also warns against pumping faster than the well can recover; on a weak well, a smaller rated flow is the cure, not a larger pump.

Ownership and maintenance

Leave the system alone until it tells you something. Frequent short cycles usually trace to the tank or a leak, and a pump that hums without pumping may have a blocked screen or low voltage. Red Lion's troubleshooting table covers each case.

Because a 2-wire motor carries its start components inside, a failed start circuit means pulling the pump. Warranty cover is three years and runs through an authorized reseller.

Pros and cons

Pros

  • Lowest-current 1/2 HP option in the RL line.
  • Nothing to mount above ground.
  • Built-in screen and check valve.
  • Covered by a three-year maker warranty.

Cons

  • Start failures mean pulling the pump.
  • Only 212 ft of shut-off head.
  • Requires a 230 V supply.

Alternatives worth comparing

Final verdict

The RL12G05-2W2V is the straightforward pick for a moderate-depth 4 in well on 230 V, especially as a like-for-like swap for an old 2-wire pump. Prefer the 3-wire twin if you value servicing start parts without a pull.

Where to buy

Each button opens this exact model's listing. We may earn a commission on tracked links; it never changes what we publish. Disclosure

Questions buyers ask

What is the difference between the RL12G05-2W2V and RL12G05-3W2V?

Both are 1/2 HP, 230 V pumps drawing 6 A with the same 212 ft shut-off. The 2W2V has its start circuit inside the motor and wires straight to the pressure switch; the 3W2V needs an extra conductor and ships with a control box that holds the start parts.

Can I replace a 3-wire pump with this 2-wire one?

Usually, yes, provided the old control box is taken out of the circuit and the two power leads go directly from the switch to the pump. The spare third conductor is left unused. Have an electrician confirm the cable and connections.

How much water does it deliver?

Red Lion rates the RL12 series at 12 GPM. Actual flow depends on total head: it falls as the pumping level, tank pressure and pipe friction rise, reaching zero at the 212 ft shut-off head.

Does it come with a pressure switch?

No. Submersibles run from a separate pressure switch, usually mounted on the tank tee near the pressure tank. Make sure its contacts are rated for the motor, or use a contactor as Red Lion's manual describes.