If there is no water and the breaker has not tripped, check whether the pressure switch is closing and receiving voltage, then whether a low-pressure cut-off or control box overload has shut the pump off. On a jet pump, check that it has not lost prime. If the pump runs but delivers nothing, suspect a low well, a clogged screen or a stuck check valve.
Safety before you start
Many well pumps run on high-voltage circuits, and the switch, control box and wiring stay dangerous even when the pump is idle. Red Lion's troubleshooting guide puts a hazardous voltage warning at the top of its submersible section and leaves voltage checks at the switch and control box to qualified electricians. Its manuals also warn never to take apart the pump or motor yourself. Everything below that involves opening a cover should start with the breaker off.
Note what you hear before you change anything. A silent pump, a humming pump, a clicking switch and a pump that runs without building pressure point in different directions, and the order of checks below follows that split.
Breaker not tripped but no water
A breaker that looks fine can still hide a power problem. A double-pole breaker can lose one leg, a fuse in a separate disconnect can blow, and terminal screws can loosen. Red Lion's first two causes for a jet pump that will not start are no power reaching the pressure switch, from blown fuses, open switches or loose connections, and a pressure switch that has not closed.
For a submersible, Red Lion's guide tells the electrician to check voltage in three places: at the fuse box, at the pressure switch terminals and at the control box or disconnect. Wherever the voltage disappears is where the fault is. If the house is on a generator after an outage, the generator may not supply enough voltage to start the motor at all.
- Reset the breaker fully off, then on, even if it looks set.
- Check any separate fused disconnect near the tank or wellhead.
- Read the pressure gauge: is pressure below the switch cut-in?
- With power off, look inside the switch for burned contacts or loose wires.
- Have an electrician confirm voltage at the switch and control box.
Pressure switch and low-pressure cut-off
If the gauge reads below cut-in and the contacts are open, the switch is not doing its job. Red Lion's charts treat a faulty pressure switch simply: replace it. Before you do, check for a low-pressure cut-off lever. Switches fitted with that option lock the pump out when pressure falls well below cut-in, which commonly happens after an outage, a burst pipe or a lost prime. The Red Lion submersible manual lists resetting the low-pressure cut-off switch as a fix for a pump that will not start.
The Square D pressure switch guide covers adjustment and the reset lever in detail.
Control box and overloads on submersible pumps
Three-wire submersible pumps have a control box above ground, and it is a common failure point. Red Lion's guide says that on 1-1/2 through 3 hp systems you can push the red overload reset buttons on the bottom of the control center. Its RL-series manual lists a tripped overload as a cause of a pump that will not start and resets for both the overload and any low-pressure cut-off.
If the overload trips again, stop resetting it. Red Lion lists low or high voltage, undersized wire, a control box of the wrong horsepower or voltage, and a failed start or run capacitor. It warns that capacitors can hold a charge after disconnection, so testing them is an electrician's job. Two-wire pumps have no control box; their starting parts are inside the motor.
Pump runs but delivers no water
If you can hear the pump running yet the pressure never rises, the problem is water supply or the pipe. For jet pumps, Red Lion's first causes are a pump not fully primed, a suction lift that is too great, and a foot valve that is out of the water, buried in mud or plugged. After a power outage or a long draw, a jet pump often loses prime and must be refilled through its priming port before it will pump again.
For submersibles, Red Lion points to a well that draws down too far while the pump runs, a partly plugged intake screen, stuck check valves and low voltage that slows the motor. In a low-yield well the cure may be setting the pump lower, at least 5 ft above the bottom, or restricting the flow so the pump never outruns the well. A leaking drop pipe also stops pressure building; Red Lion's test is to raise the pipe one length at a time until water stands in it.
When the breaker keeps tripping
A well pump that trips its breaker as it starts usually has an electrical fault or a jammed pump. Red Lion lists voltage outside 5% of the nameplate rating, wire too small for the run, grounded or shorted cable splices or windings, and failed capacitors in the control box. None of these are owner repairs. Call a well professional, and mention whether it trips instantly or after running, which helps them narrow it down. If the pump is beyond repair, the deep well submersible pump list and shallow well jet pump list compare replacements.
Common mistakes
- Assuming the breaker is fine because the handle looks set.
- Resetting a control box overload over and over without finding the cause.
- Running a jet pump dry for long periods after it has lost prime.
- Opening the pressure switch or control box with power still on.
- Replacing the pump when a low-pressure cut-off had simply locked it out.
Products that fit

Square D FSG2J21CP 30/50 PSI Pressure Switch
Common 30/50 psi pressure switch, often the part that fails first.

Red Lion RL12G05-3W2V Deep Well Submersible Pump
Three-wire submersible from Red Lion's RL series that uses a control box.

Red Lion RJS-50-PREM Shallow Well Jet Pump
Cast iron shallow well jet pump that must stay primed to deliver water.

Amtrol WX-202 Well-X-Trol Pressure Tank
Diaphragm tank; a waterlogged tank causes rapid cycling, not total loss of water.
Questions readers ask
Why is my well pump not working when the breaker is not tripped?
Power may still be missing past the breaker: a lost leg, a blown fuse in a disconnect or a loose wire. The pressure switch may have failed or locked out on low pressure, or a control box overload may have tripped. On jet pumps, lost prime is common.
Why is my well pump not working after a power outage?
Jet pumps often lose prime when power is off, and switches with a low-pressure cut-off lock the pump out if pressure fell too far. Reprime the pump or reset the lever once you know why pressure dropped.
Where is the reset button on a well pump?
Most pumps have none on the motor. Three-wire submersibles may have overload reset buttons on the control box, and some pressure switches have a low-pressure cut-off lever. Red Lion mentions control center reset buttons on its larger systems.