A 2-wire submersible has its starting components inside the motor, so two power wires plus ground run from the pressure switch straight down the well. A 3-wire pump keeps its capacitor and relay in a control box above ground, which must match the motor's horsepower and voltage; Flotec warns a 3-wire motor run without its box will burn out.
What the wire count means
Both types are single-phase motors that need help to start. The difference is where that help sits. In a 2-wire pump it is built into the motor at the bottom of the well. In a 3-wire pump the starting capacitor and relay sit in a control box on the wall, joined to the motor by red, yellow and black leads plus a ground.
Flotec's manual draws both. Its 2-wire figure shows two black power wires and a green ground running from the pressure switch to the motor, and it notes that a control box is not required. Its 3-wire figure routes power from the switch to the control box, then down the well with color-coded leads that must match: yellow to Y, red to R, black to B. Red Lion's model names say which you have, with 2W or 3W in the part number.
| Feature | 2-wire | 3-wire |
|---|---|---|
| Conductors down the well | 2 power + ground | 3 power + ground |
| Starting parts | Inside the motor | In an above-ground control box |
| Control box | Not required | Required; must match HP and voltage |
| Red Lion model example | RL12G07-2W2V | RL12G05-3W2V (box included) |
| Flotec 2-wire examples | FP2211, FP2212, FP2222 | Not listed in the 2-wire sheet |
Figures: Flotec owner's manual FP874, 4 in submersible pumps, two and three wire; Red Lion RL Series 4 in submersible well pump specifications; Flotec 2-wire 4 in submersible well pump sell sheet.
Wiring a 2-wire pump
A 2-wire installation is the simplest well circuit. Power comes from a fused disconnect to the line terminals of the pressure switch. The two load terminals feed the two drop cable conductors, and the ground runs continuously from the panel to the motor. Flotec's manual states that 2-wire motors do not use a control box; the wire runs from the pressure switch directly to the motor.
Voltage matters. The Flotec FP2211 is a 115 V pump, while the FP2212 and FP2222 are 230 V. Flotec's notes for Figure 1B say the drawing is correct for 115 and 230 V 2-wire motors only. Red Lion encodes the same detail at the end of its part numbers, with 1V for 115 V and 2V for 230 V.
- Shut off and lock out the breaker feeding the well circuit.
- Bring line power to the pressure switch line terminals.
- Connect the drop cable power wires to the load terminals.
- Join the ground to the switch, casing and motor ground.
- Bond metal casing and pipe as Flotec's grounding notes require.
Wiring a 3-wire pump and its control box
A 3-wire system adds one stop. Power runs from the disconnect to the pressure switch, from the switch to the control box line terminals, and from the box down the well. The box must match the motor. Flotec's selection table pairs each motor with a specific box by horsepower and voltage, and Red Lion's chart for fuses blowing lists a box with the wrong horsepower or voltage as a cause.
Flotec adds two practical points. Mount the box vertically with the top up so the starting relay works and the overload does not nuisance trip, and keep it out of direct sun, since high ambient temperature is another cause Red Lion lists. If the main overload trips, Flotec says to look for a shorted capacitor, voltage problems or a locked pump. For 1-1/2 HP and larger motors, Flotec calls for a magnetic starter so the pressure switch is not damaged.
Wire size and run length
Long drop cables lose voltage, and a starved motor runs hot and slow. Flotec's tables give the maximum copper cable length from the service to the motor for each size. Because a 3-wire cable carries the starting current differently, its limits are shorter than a 2-wire cable of the same gauge for the same pump. For aluminum cable Flotec says to go up two sizes.
Red Lion's troubleshooting guide asks that running voltage stay within plus or minus 5 percent of the nameplate. If a pump trips on start or runs slowly, have the voltage read at the control box or disconnect while the pump runs, before suspecting the motor.
| Wire size | 2-wire | 3-wire |
|---|---|---|
| 14 AWG | 438 | 348 |
| 12 AWG | 697 | 553 |
| 10 AWG | 1112 | 883 |
Figures: Flotec owner's manual FP874, 4 in submersible pumps, two and three wire.
Which to choose, and troubleshooting differences
A 2-wire pump has fewer parts above ground and no box to buy or mount, which makes replacement of a like pump quick. Its drawback is that a failed internal starting part means pulling the pump. A 3-wire pump lets you replace a capacitor or relay at the wall, and Red Lion's guide lists several 3-wire-only faults that are checked there: loose or broken wires in the box, a wrong box and a blown capacitor. Capacitors can hold a charge after power is off, so leave that work to an electrician.
When replacing a pump, match what is in the well unless you plan to change the cable. Red Lion's RL12G05-3W2V ships with its control box, while the RL12G07-2W2V is a 2-wire pump. The deep well submersible list shows both types side by side.
Common mistakes
- Wiring a 3-wire pump straight to the pressure switch without its control box.
- Using a control box rated for a different horsepower or voltage.
- Mounting the control box sideways or in direct sun.
- Running undersized cable down a long drop to the motor.
- Mixing up the red and yellow leads at the control box.
Products that fit

Flotec FP2211 115 V Deep Well Submersible Pump
Flotec 1/2 HP 2-wire pump for 115 V circuits, with no control box needed.

Flotec FP2212 230 V Submersible Well Pump
The same 1/2 HP Flotec 2-wire design for 230 V circuits.

Red Lion RL12G05-3W2V Deep Well Submersible Pump
Red Lion 1/2 HP 3-wire pump that ships with its matched control box.

Red Lion RL12G07-2W2V 2-Wire Submersible Well Pump
Red Lion 3/4 HP 2-wire pump for 230 V with starting parts in the motor.
Questions readers ask
How do I know if my well pump is 2-wire or 3-wire?
Look for a control box on the wall near the pressure switch. If there is one, the pump is almost certainly 3-wire. You can also count the insulated conductors in the drop cable, not counting the bare or green ground.
Can I replace a 3-wire pump with a 2-wire pump?
Yes, if the cable and voltage suit the new motor. A 2-wire pump needs no control box, so the old box is removed and the pressure switch feeds the cable directly. Confirm the cable size against the maker's length table.
Does a 2-wire well pump need a control box?
No. Flotec states that 2-wire motors do not use a control box and are wired from the pressure switch directly to the motor. The starting parts are inside the motor itself, so there is nothing extra to mount on the wall.
What happens if a 3-wire pump runs without a control box?
It will not start properly, and Flotec warns that operating a 3-wire motor without its control box will burn it out. Always replace a failed box with one matched to the motor horsepower and voltage.